Swimming Pool Pump Troubleshooting Guide
Swimming Pool Pump Troubleshooting Guide

1. Pump Failure to Start
Symptoms: No response or humming sound
Causes:
• Phase loss (voltage <200V)
• Failed start capacitor (capacitance drop >20%)
• Impeller mechanical lock
Solutions:
① Test input voltage with multimeter (balanced 380V±5%)
② Measure capacitor with LCR meter (refer to nameplate value)
③ Rotate shaft manually; if resistance >2N·m, disassemble to clean impeller
2. Abnormal Noise
High-pitched squeal:
• Bearing wear (vibration >4.5mm/s)
• Dry running mechanical seal
Low-frequency vibration:
• Loose base bolts (torque <25N·m)
• Cavitation (NPSH margin insufficient)
Procedures:
① Locate noise source with vibration analyzer
② Replace bearings with SKF 6205-2RS (60% grease fill)
③ Inject hydrodynamic lubricant (e.g., Pacer Pool Lube)
3. Insufficient Flow
Diagnostic parameters:
• Inlet/outlet differential pressure >15psi
• Motor current <70% rated value
Root causes:
• Impeller erosion (vane thickness <50% original)
• Clogged strainer basket (ΔP >5psi)
• Pipe diameter reduction (<80% pump size)
Corrective actions:
① Measure impeller dimensions per ANSI/HI 1.1
② Inspect pipe elbows with borescope
③ Verify system flow using Q=πD²/4√(2gH)

4. Water Leakage
Leak types:
• Shaft seal weepage (>3 drops/min)
• Casting defects (revealed in 30psi pressure test)
Repair standards:
• Replace mechanical seal (John Crane Type 152)
• Apply metal-filled epoxy for casing repair (cure >24h)
5. Overheating Trip
Critical thresholds:
• Motor temperature rise >80℃
• Insulation resistance <1MΩ (500V megger test)
Countermeasures:
① Clean cooling fins (air pressure ≤0.3MPa)
② Check winding balance (>10% imbalance requires rewinding)
③ Adjust VFD carrier frequency (recommended 4kHz)
Finally
Pro Tips:
• Monthly lubricate seals with NLGI #2 lithium grease
• Winterize with 25% antifreeze solution
• VFD pumps: Avoid operation below 30% rated speed